Well – Ven GVJ-6

  Well
Name
Type of well Well depth in
feet
Water
amoun
t %
API date of
initial
treatment
  GVJ-6 pumping well 4940 30% 13.9 18-Jun-04
Well problem High pressure 800 to 1000 psi in the well head
Solution Mix 4 drums of KX-9 and 1 drum of KH-30 with 265 barrels of gasoil
and pump downhole. Wait 48 hours before starting well production.
No continuous injection.


GVJ-6 oil production (BNPD)
Before 89
After 158
Increase 69
Perc. Increase 78%